Tubo sanitario de acero inoxidable: acabado superficial Ra y por qué importa
La Ra interior determina la limpiabilidad: 0,8 µm para alimentación y lácteos, 0,4 µm para farmacia, y la ruta de pulido que permite alcanzar cada valor.
Por Dakai Steel Technical Team

In a sanitary line the wetted surface is part of the process, not a finish detail. Internal roughness Ra sets how much product, mineral scale and biofilm survive a CIP cycle, and how long a heat-denatured protein layer stays cleanable. Two numbers decide most specifications: Ra ≤ 0.8 µm for food and dairy, Ra ≤ 0.4 µm for pharmaceutical and biotech. Below: how each is measured, reached and verified.
What Ra measures
Ra is the arithmetical mean deviation of the roughness profile, in micrometres: a stylus traces the bore over a sampling length and averages every deviation from the mean line, typically with a 0.8 mm cut-off and a 2 or 5 µm tip. Lower Ra means a shallower profile and fewer valleys for residue to occupy. Ra is an average, so a ground surface and an electropolished one can report the same Ra while differing in Rz, the maximum peak-to-valley height — and it is the peaks that shield bacteria from flow. Roughness says nothing about waviness, weld bead profile or dead legs.
Food versus pharma: 0.8 µm versus 0.4 µm
Dairy, beverage, brewery and food process lines are normally specified at Ra ≤ 0.8 µm on product-contact surfaces, about 32 µin. Mechanical polishing to 320–400 grit plus passivation reaches that level, survives daily caustic and acid CIP, and tolerates the occasional scratch without turning it into a bacterial harbour. It is also the level turbulent cleaning flow can reach to the bottom of the profile; 3-A SSI cleanability practice and most US dairy specifications sit here.
Pharmaceutical, biotech, WFI and aseptic service moves to Ra ≤ 0.4 µm, about 15 µin; the ASME BPE SF1 class is 0.38 µm. At 0.4 µm, residue and the organisms feeding on it have fewer anchoring points, and cleaning validation gets shorter. The catch is that 0.4 µm must hold across the whole wetted path: longitudinal weld, orbital weld, fittings, valve bodies, dead legs. A 0.4 µm tube with an unpolished weld is a 0.8 µm system with a dirty joint.
Electropolish versus mechanical polish
Mechanical polishing cuts metal with abrasives in steps: 120–180 grit to grind the weld and remove mill scale, then 240, 320 and 400 grit, each pass erasing the scratches of the last. It is cheaper, works at any diameter, and is the normal route to 0.8 µm. Electropolishing goes further: the tube is made the anode in a phosphoric–sulfuric electrolyte, and current removes a thin, preferentially levelled metal layer from the peaks. Ra drops by roughly 40–60%, embedded iron and the disturbed layer left by abrasives are removed, chromium is enriched in the passive film. Electropolish refines the surface it is given; it cannot rescue a badly ground weld. The usual pharma specification is 400 grit plus electropolish, stated as Ra ≤ 0.4 µm and Rz ≤ 3.0 µm.
Standards: DIN 11850, 3-A, ASTM A270
The standards divide the work. DIN 11850 fixes dimensions and tolerances for hygienic welded tube: OD 12.7 to 219 mm, wall 1 to 3 mm, so ferrules and fittings mate without matching drawings. ASTM A270 covers welded austenitic sanitary tube and leaves the polished finish to be agreed as a Ra value and grit sequence; seamless tube follows A269: OD 6 to 152 mm, wall 1 to 4 mm. 3-A SSI adds cleanability criteria for the assembled line: no crevices, ledges or undrainable low points.
Testing: roughness report and borescope
Sanitary tube needs more than a mill certificate. We hydrotest each lot, run eddy-current testing on welded tube, and inspect the bore with a borescope for bead height, discolouration, grinding marks and residual pits. The roughness report states instrument, tip radius, cut-off and Ra and Rz at three or four angular positions per length, including a reading across the weld. Passivation is confirmed to ASTM A967, and a ferroxyl test can be added for 0.4 µm material. A sample length for your own roughness check settles finish arguments before the order ships.
Send the medium, the Ra requirement and the size range, and we will quote the tube, finish route and inspection documents.